Epinephrine

HPLC Analysis of Six Catecholamines on Reversed-Phase Aromatic Phases. Buffered Mobile Phase
Conditions of Experiment
Column:
Separation Modes:
Column Dimenstions:
Mobile Phase:
Detection:
Sample:
Injection:
Flow rate:
Analytes
Class of compounds: Amino acid, Aromatic base, Catecholamine, Drug, Neurotransmitter, Stimulant, Supplement
Nature of compounds: Acidic, Basic, Hydrophilic, Polar, Zwitterionic
Compounds: Epinephrine, Norephedrine, Ephedrine, Phenylalanine, Tryptophan, DOPAC
HPLC Separation of Four Catecholamines on Amaze SC Mixed-Mode Column with LC/MS Compatible Conditions
Conditions of Experiment
Column: Amaze SC
Separation Modes: reversed-phase cation-exchange
Column Dimenstions: 3.0x100 mm, 5 μm, 100A
Mobile Phase: 40% ACN with 40 mM AmFm pH 3
Detection: UV 250 nm
Sample: 0.3 mg/ml
Injection: 2 μL
Flow rate: 0.6 ml/min
Analytes
Class of compounds: Aromatic base, Catecholamine, Drug, Neurotransmitter, Stimulant
Nature of compounds: Basic, Hydrophilic, Polar
Compounds: Epinephrine, Norepinephrine, Dopamine, Ephedrine
HPLC Analysis of Epinephrine and Phenylephrine on Heritage C18 Column According to US Pharmacopeia
Conditions of Experiment
Column: Heritage С18
Separation Modes: reversed-phase
Column Dimenstions: 4.6 x 150 mm, 5 um, 100A
Mobile Phase: Water/MeOH ( 50/50) with 0.1% 1-octanesulfonic acid adjust to pH 3.0 with H3PO4
Detection: UV 254 nm
Sample: 0.3 mg/ml
Injection: 5 uL
Flow rate: 1 mL/min
Analytes
Class of compounds: Catecholamine, Drug, Neurotransmitter
Nature of compounds: Basic, Hydrophilic, Polar
Compounds: Epinephrine, Phenylephrine
Separation of Neurotransmitters on Coresep 100 Column in Reversed-Phase and Cation-Exchange Modes
Application description

Catecholamines (neurotransmitters) are derivatives of the amino acid tyrosine. DOPA, tyrosine, phenylalanine, norepinephrine, epinephrine, and dopamine. Fast and efficient method with base-line separation was achieved on Coresep 100 column. All compounds are separated by combination of reversed-phase and cation-exchange mechanisms. Peak order and retention time can be changed by switching from TFA to ammonium formate in the mobile phase, by adjusting mobile phase composition and by changing pH. The method is fully compatible with mass spectroscopy and can be used for fast analysis of neurotransmitters in biofluids. regular. Method can be used a replacement for analysis of neurotransmitters by UPLC with ion-pairing reagents.

Conditions of Experiment
Column: Coresep 100
Separation Modes: reversed-phase and cation-exchange
Column Dimenstions: 3.2 x 100 mm, 2.7 um, 90A
Mobile Phase: ACN gradient from 5% to 10% in 5 min, buffer gradient - Ammonium formate pH 2.9 from 5 to 25 mM in 5 min
Detection: UV 270 nm, ELSD
Sample: 0.3 mg/ml
Injection: 1 uL
Flow rate: 1 ml/min
Analytes
Class of compounds: Amino acid, Aromatic base, Catecholamine, Drug, Neurotransmitter, Supplement
Nature of compounds: Basic, Hydrophilic, Polar, Zwitterionic
Compounds: Dopamine, Tyrosine, Phenylalanine, Norepinephrine, Epinephrine, DOPA