Bromide ion

HPLC Analysis of Divalent Cations and Corresponding Counterions on Amaze TCH Mixed-Mode Column
Conditions of Experiment
Column: Amaze TCH
Separation Modes: HILIC, anion-exchange, cations-exchange
Column Dimenstions: 3.0x100 mm, 3 um, 100A
Mobile Phase: ACN
from 75% to 30%, AmFm from 40 mM pH 4.0 to 40 mM pH 2.5
Detection: ELSD
Sample: 0.3-0.5 mg/ml
Injection: 3 uL
Flow rate: 0.6 ml/min
Analytes
Class of compounds: Contaminant, Inorganic acid, Inorganic anion, Inorganic cation, Organic acid
Nature of compounds: Acidic, Basic, Hydrophilic, Polar
Compounds: Iodide ion, Nitrate ion, Bromide ion, Bromate Ion, Calcium ion, Persulfate ion, Magnesium ion, Phosphate Ion, Nickel ion, Copper ion, Zinc ion, Barium ion
HPLC Separation of Monovalent Inorganic Cations and Anions in HILIC, Cation- and Anion-Exchange Modes on Amaze TCH
Conditions of Experiment
Column: Amaze TCH
Separation Modes: HILIC, cation-exchange, anion-exchange
Column Dimenstions: 4.6x150 mm, 3 um, 100A
Mobile Phase: 73% ACN with 20 mM AmFm pH 2.7
Detection: Corona CAD
Sample: 0.5 mg/ml
Injection: 2 ul
Flow rate: 1 ml/min
Analytes
Class of compounds: Inorganic anion, Inorganic cation, Organic acid
Nature of compounds: Acidic, Basic, Hydrophilic, Polar
Compounds: Iodide ion, Potassium ion, Sodium ion, Lithium ion, Bromide ion, Chloride Ion
HPLC Analysis of Glycine-Zinc Formulation on Amaze SC in Reversed-Phase and Cation-Exchange Modes
Conditions of Experiment
Column: Amaze SC
Separation Modes: reversed-phase, cation-exchange and anion-exclusion
Column Dimenstions: 4.6x50 mm, 3 μm, 100A
Mobile Phase: 10% ACN, TFA from 0.05% to 0.25% in 3 min, 5 min hold
Detection: Corona CAD
Sample: 0.5 mg/ml
Injection: 2 μL
Flow rate: 1 ml/min
Analytes
Class of compounds: Amino acid, Inorganic anion, Inorganic cation, Organic acid, Supplement
Nature of compounds: Acidic, Basic, Hydrophilic, Polar, Zwitterionic
Compounds: Bromide ion, Glycine, Zinc ion
HPLC Analysis of Polar Environmental Contaminants on Amaze HD Mixed-Mode Column with LC/MS Compatible Conditions
Conditions of Experiment
Column: Amaze HD
Separation Modes: HILIC, cation-exchange, anion-exclusion
Column Dimenstions: 4.6x150 mm, 3 μm, 100A
Mobile Phase: 78% ACN with 44 mM AmFm pH 3
Detection: Corona CAD
Sample: 0.3 mg/ml
Injection: 2 μL
Flow rate: 1 ml/min
Analytes
Class of compounds: Inorganic acid, Inorganic anion, Inorganic cation, Organic acid
Nature of compounds: Acidic, Basic, Hydrophilic, Polar
Compounds: Perchlorate ion, Chlorate ion, Bromide ion, Thiophosphate ion, Ethylphosphonate ion, Phosphonate ion, Potassium ion, Sodium ion, Phosphate Ion
HPLC Analysis of Polar Environmental Contaminants on Amaze TH Mixed-Mode Column with LC/MS Compatible Conditions
Conditions of Experiment
Column: Amaze TH
Separation Modes: HILIC, cation-exchange, anion-exclusion
Column Dimenstions: 4.6x150 mm, 3 μm, 100A
Mobile Phase: 80% ACN with 30 mM AmFm pH 3
Detection: Corona CAD
Sample: 0.3 mg/ml
Injection: 2 μL
Flow rate: 1 ml/min
Analytes
Class of compounds: Aromatic acid, Inorganic anion, Inorganic cation, Organic acid
Nature of compounds: Acidic, Basic, Hydrophilic, Polar
Compounds: Cyanuric acid, Perchlorate ion, Chlorate ion, Trifluoroacetic acid, Bromide ion, Bromate Ion, Phosphonate ion, Potassium ion, Phosphate Ion
HPLC Analysis of Musinex DM Severe Congestion and Cough Formulation on Heritage MA Mixed-Mode Column
Application description

Most of the over-the-counter cold and cough remedies contain a complex mixture of basic, acidic, neutral, hydrophilic, and hydrophobic compounds. Analysis of drugs and counterions usually require two methods - one for the active drug and related impurities and another one for analysis of counterions. The method can be simplified by switching to mixed-mode stationary phases. Mixed-mode stationary phases have ion-pairing reagent attached to the surface of silica gel. The presence of ionizable groups on the surface allows us to achieve 2-D separation on a single column. We have developed a reliable, robust high-efficiency method for analysis of active and inactive ingredients of Mucinex on Heritage MA mixed-mode column. The active ingredients of the formulation include guaifenesin and dextromethorphan. Guaifenesin is a hydrophilic organic compound that is used as a drug that is used to help to remove mucus from the mouth due to the common cold and flu. Dextromethorphan is a hydrophobic basic compound, which is used as an over-the-counter cough suppressant. Excipients are hydrophilic and hydrophobic in nature and are added to improve taste and increase the stability of the formulation. Heritage MA column shows exceptional peak shape and does not demonstrate poor peak shape for basic analytes like dextromethorphan. Heritage MA column can be used for analysis and validation of methods for separation of hydrophobic, hydrophobic basic, hydrophobic acidic and hydrophilic acidic compounds. There are several mechanisms available to be used with this column - reversed-phase, anion-exchange, cation-exclusion, and combination of the above.

Conditions of Experiment
Column: Heritage MA
Separation Modes: reversed-phase, cation-exclusion, anion-exchange
Column Dimenstions: 4.6x150 mm, 3 um, 100A
Mobile Phase: 8% ACN with 30 mM NaH2PO4 pH 3.1
Detection: UV 255
Sample: various
Injection: 3 uL
Flow rate: 1 ml/min
Analytes
Class of compounds: Amines, Aromatic base, Aromatic compound, Drug, Inorganic anion, Organic acid
Nature of compounds: Acidic, Basic, Hydrophilic, Hydrophobic, Neutral, Polar
Compounds: Bromide ion, Dextromethorphan, Guaifenesin
HPLC Analysis of Seven Anions on Heritage MA Mixed-Mode Column
Application description

Organic and inorganic acids are part of many formulations including pharmaceutical and nutraceuticals. These compounds are very often very polar and acidic, and either require expensive ion-chromatography or the use of ion-pairing reagents. Ion-pairing reagents are not compatible with mass spectrometry. Mixed-mode columns allow the utilization of the ion-pairing reagent attached to the surface of silica gel to retain these anionic compounds. The retention is provided by weak reverse-phase and by a medium or strong anion-exchange mechanism. The retention time is controlled by the amount of ACN, buffer pH and buffer concentration. Stronger and more hydrophobic acids will retain longer, and their elution can be effectively controlled by changing the ionization state at a different pH. This method is compatible with major detection techniques ( (ELSD, CAD, RI, UV and mass spec). This method can be used for the analysis of basic hydrophobic drugs and their acidic counter-ions in one run. Acidic hydrophobic drugs and related impurities can be analyzed on this mixed-mode HPLC column.

Conditions of Experiment
Column: Heritage MA
Separation Modes: anion-exchange
Column Dimenstions: 4.6x150 mm, 3 um, 100A
Mobile Phase: 60% ACN with 60 mM AmFm pH 3
Detection: ELSD, 50°C
Sample: 1 mg/ml
Injection: 3 uL
Flow rate: 1 ml/min
Analytes
Class of compounds: Inorganic anion, Organic acid
Nature of compounds: Acidic, Hydrophilic, Polar
Compounds: Phosphate Ion, Bromate Ion, Bromide ion, Chloride Ion, Iodide ion, Trifluoroacetic acid, Perchlorate ion
Simultaneous HPLC Analysis of Potassium Ion and Bromide Ion on Amaze TH Mixed-Mode Column
Conditions of Experiment
Column: Amaze TH
Separation Modes: cation-exchange, anion-exchange
Column Dimenstions: 4.6x150 mm 5 um, 100A
Mobile Phase: 20% ACN with 20 mM AmAc pH 4
Detection: ELSD
Sample: 1 mg/ml
Injection: 3 uL
Flow rate: 1 ml/min
Analytes
Class of compounds: Inorganic anion, Inorganic cation, Organic acid
Nature of compounds: Acidic, Basic, Hydrophilic, Polar
Compounds: Bromide ion, Potassium ion