Salicylic acid
Salicylic acid
Salicylic acid
Select Applications
Direct HPLC Analysis of Salicylic Acid in Human Urine on Heritage MA Mixed-Mode Column
Direct HPLC Analysis of Salicylic Acid in Human Blood on Heritage MA Mixed-Mode Column
HPLC Analysis of Five Acidic Drugs on Heritage MA Mixed-Mode Column
HPLC Analysis of Drug Composition on Heritage C18 Column According to US Pharmacopeia
Direct HPLC Analysis of Salicylic Acid in Human Urine on Heritage MA Mixed-Mode Column
Conditions of Experiment
Column: | Heritage MA |
Separation Modes: | reversed-phase and anion-exchange |
Column Dimenstions: | 4.6x150 mm, 3 um, 100A |
Mobile Phase: | 75% ACN with 15 mM AmAc pH 4 |
Detection: | 235 nm |
Sample: | 0.1 mg/ml |
Injection: | 1 uL |
Flow rate: | 1 ml/min |
Analytes
Class of compounds: | Aromatic acid, Drug, Organic acid |
Nature of compounds: | Acidic, Hydrophilic, Polar |
Compounds: | Salicylic acid |
Direct HPLC Analysis of Salicylic Acid in Human Blood on Heritage MA Mixed-Mode Column
Conditions of Experiment
Column: | Heritage MA |
Separation Modes: | reversed-phase and anion-exchange |
Column Dimenstions: | 4.6x150 mm, 3 um, 100A |
Mobile Phase: | 75% ACN with 15 mM AmAc pH 4 |
Detection: | 235 nm |
Sample: | 0.1 mg/ml |
Injection: | 1 uL |
Flow rate: | 1 ml/min |
Analytes
Class of compounds: | Aromatic acid, Drug, Organic acid |
Nature of compounds: | Acidic, Hydrophilic, Polar |
Compounds: | Salicylic acid |
HPLC Analysis of Five Acidic Drugs on Heritage MA Mixed-Mode Column
Conditions of Experiment
Column: | Heritage MA |
Separation Modes: | reversed-phase and anion-exchange |
Column Dimenstions: | 4.6x150 mm, 3 um, 100A |
Mobile Phase: | 35% ACN with 0.15% sulfuric acid |
Detection: | 255 nm |
Sample: | 0.2-0.4 mg/ml |
Injection: | 2 uL |
Flow rate: | 1 ml/min |
Analytes
Class of compounds: | Aromatic acid, Drug, Organic acid |
Nature of compounds: | Acidic, Hydrophilic, Hydrophobic, Neutral, Polar |
Compounds: | Aspirin, Salicylic acid, Ketoprofen, Naproxen, Ibuprofen |
HPLC Analysis of Drug Composition on Heritage C18 Column According to US Pharmacopeia
Conditions of Experiment
Column: | Heritage С18 |
Separation Modes: | reversed-phase |
Column Dimenstions: | 4.6 x 100 mm, 5 um, 100A |
Mobile Phase: | MeOH/H2O/AcOH 30/67/3 |
Detection: | UV 275 nm |
Sample: | 0.2 mg/ml |
Injection: | 5 uL |
Flow rate: | 1 mL/min |
Analytes
Class of compounds: | Aromatic acid, Aromatic compound, Drug, Organic acid, Stimulant, Xanthine |
Nature of compounds: | Acidic, Hydrophilic, Hydrophobic, Neutral, Polar |
Compounds: | Acetaminophen, Caffeine, Aspirin, Benzoic acid, Salicylic acid |